NDT inspection that finds flaws before they fail

Steinol Solutions is a specialist inspection company carrying out a wide range of non-destructive testing (NDT), inspection and calibration services, most of them at the client’s site. Our qualified team brings inspection knowledge that spans oil and gas products, from drill pipe and BHA tools to welded structures and plant.

We also carry out NDT inspection and efficiency testing of structures, turbines and generators, and third-party pre- and post-shipment inspections, so equipment is checked before it leaves the supplier and again when it arrives.

  • DS-1
  • ASNT member
  • IADC member
  • Pakistan Engineering Council
  • ISOQAR certified
Four engineers in hard hats and blue workwear examine and mark a large steel pipe inside a workshop.

Why NDT

Test the part without damaging it

Non-destructive testing examines a material, weld or component without cutting it up or affecting its fitness for use. That means you can inspect the actual part that will go into service, not a sample, and put it straight back to work once it passes.

NDT is how fabricators prove weld quality, how operators catch fatigue cracks and corrosion before they cause a failure, and how buyers confirm that what was delivered matches what was ordered. Used at the right points, it reduces unplanned shutdowns, downhole failures and safety incidents.

Choosing a method

Which NDT method do you need?

No single method finds everything. The right choice depends on the material, where the flaw is likely to be and what your code or client specifies. As a starting point:

If you are not sure, send us the drawing, specification or a photo of the part and we will recommend a method.
MethodFindsWorks onTypical use
Industrial radiography (RT)Internal flaws: porosity, inclusions, lack of fusion, voidsMost metalsWeld acceptance, castings, pipework
Positive material identification (PMI)Wrong or mixed-up alloy gradesMost metals and alloysIncoming material, alloy piping, replacement parts
Liquid penetrant testing (PT)Surface-breaking cracks and porosityNon-porous materials, including non-magnetic metalsAluminium and stainless parts, non-magnetic drill collars
Magnetic particle inspection (MPI)Surface and near-surface cracksFerromagnetic steels and cast ironWelds, lifting gear, forklift tines, BHA threads

Our services

NDT, inspection and calibration services

NDT methods

  • Industrial radiography, film and computed
  • Positive material identification by XRF
  • Liquid penetrant testing, visible and fluorescent
  • Magnetic particle inspection, AC yoke and wet fluorescent

Oilfield and plant

  • Drill pipe, casing and tubing inspection
  • Drill collars, subs, kelly and BHA tools
  • NDT inspection and efficiency testing of structures, turbines and generators
  • Third-party pre- and post-shipment inspection

Calibration

  • Pressure, pit and coating thickness gauges
  • Vernier calipers and surface profile gauges
  • Thermometers
  • Verifiable SSPL calibration certificates

How we work

From enquiry to inspection report

  1. 01

    Define the scope

    We confirm what needs inspecting, the method, and the code, specification or customer criteria the results will be judged against.

  2. 02

    Plan the site work

    We agree access, timing, surface preparation and any safety controls, such as the controlled area needed for radiography.

  3. 03

    Inspect

    Qualified technicians carry out the testing at your site and record every indication found.

  4. 04

    Report and certify

    Results are evaluated against the agreed acceptance criteria and issued in a numbered SSPL report or certificate that can be verified online.

Questions

NDT inspection questions

Do you carry out NDT at our site?

Yes. Our NDT, inspection and calibration services are designed to be carried out at the client’s site, including field radiography at customer locations.

Which acceptance criteria do you inspect to?

The ones that apply to your job. For drill pipe this is often DS-1; for welds it is usually the code or specification the item was built to; and we can work to customer-supplied criteria. The criteria used are stated on the report.

Can I use more than one method on the same job?

Often you should. For example, radiography shows internal weld flaws while magnetic particle or penetrant testing is better at fine surface cracks. We will recommend a combination that covers the defects you are worried about.

How does my client know the report is genuine?

Every SSPL report and certificate carries a unique number that can be checked on our certificate verification page.

Need welds radiographed, an alloy confirmed, a drill string inspected or gauges calibrated? Send us the scope and we will recommend the right test.