Liquid penetrant testing for surface cracks

Liquid penetrant testing is probably the most widely used NDT method. It finds cracks, porosity and laps that break the surface of a part, and it works on almost any non-porous material, including aluminium, stainless steel and other non-magnetic metals where magnetic particle inspection cannot be used.

SSPL personnel work with both visible (colour-contrast) and fluorescent penetrants, choosing the system that suits the part, the surface and the sensitivity your specification calls for.

A technician sprays an aerosol cleaner onto a steel shaft on a workbench.

The method

How a penetrant test is done

  1. 01

    Clean

    The surface is cleaned and dried so that oil, paint, scale and dirt do not block the openings of any flaws.

  2. 02

    Apply penetrant

    A low-viscosity penetrant is applied and left for a set dwell time, drawn into surface-breaking flaws by capillary action.

  3. 03

    Remove excess

    Penetrant is carefully removed from the surface, leaving only what has entered the flaws.

  4. 04

    Develop

    A thin developer layer draws penetrant back out of the flaws, producing a visible indication much wider than the flaw itself.

  5. 05

    Inspect and report

    Indications are examined under white light (visible penetrant) or ultraviolet light (fluorescent penetrant), evaluated against your acceptance criteria and recorded.

Questions

Penetrant testing questions

When should I use PT rather than magnetic particle inspection?

Use PT on non-magnetic materials such as aluminium, austenitic stainless steel, copper alloys and titanium, including the threads of non-magnetic drill collars. On carbon and low-alloy steel, magnetic particle inspection is often preferred because it can also find flaws just below the surface.

What is the difference between visible and fluorescent penetrant?

Visible penetrant is red and read in normal light, which makes it simple to use in the field. Fluorescent penetrant glows under ultraviolet light and is more sensitive to very fine cracks, but it needs darkened viewing conditions.

What can PT not detect?

PT only finds flaws that are open to the surface. It will not show internal defects, and it is not suitable for porous materials. For internal flaws in welds and castings, radiography is the usual choice.

Talk to our team about liquid penetrant testing.